5 Simple Statements About Dp50rb Explained
5 Simple Statements About Dp50rb Explained
Blog Article
.. Web page 161 The indicator over the printer Problems happen if the adapter turns orange, along with the printing printer adapter operates. Disconnect and join the fails. electric power adapter, ability about the printer adapter again, and confirm if the printing is ordinary after one moment. Website page 163: Electrical Safety Inspection
1.two.2 Warning Labels Warning Labels Indicating Be sure to carefully read through this handbook ahead of use gadget. The following labels are a. Never area the unit on the sloped surface. Otherwise the accessible if the program product could slide, leading to personalized damage or maybe the system functions with the mobile malfunction.
Don't use any cables in addition to the cables provided with the machine by Mindray. 3. Use the cable provided with This method to attach the printer. Other cables may possibly end in electrical shock. Web page fifteen: Mechanical Security
If you end the scanning as well as picture seize, you ought to electric power off the program and disconnect the program from your AC electricity provide, then pull out AC energy cables. Web page 109: Battery Connecting Board
By continuing your pay a visit to on our Web page, you are consenting to our usage of cookies. Having said that, you are able to adjust your cookie options at any time. Cookie preference Acknowledge and Carry on
Return to your system preset interface. The option position changes into Uninstalled. The uninstalling function is exceptional to interior people.
Find improved diagnostic information and facts via prolonged look at with the anatomical structure on all linear probes
The DP-50 Specialist is an progressive, significant-performance Ultrasound Process engineered that will help you get the insights you require. The System’s potent engine and large-pace processing provide superb graphic excellent and a whole information administration Alternative.
This guide may well referring to information guarded by copyright or patents and will not Express any license underneath the patent legal rights or copyright of Mindray, or of Many others. Web site nine: Statement
iZoom™ permits correct viewing of picture from length iWorks™ Protocol can help standardize workflow and lower exam times
Notice: Around the monitor, the brightness adjustment comes before contrast. Right after readjusting the monitor’s contrast and brightness, modify all preset and peripheral settings.
Take note: Right before inserting the connector in the probe port, inspect the connector pin. If the pin is bent, don't utilize the probe until finally it's been inspected / fixed / replaced. Putting in Peripherals For that models from the supported peripherals, please check with “two.
After changing the CPU module, key file must be generated Again based on the new MAC handle and written into HDD in the device. Or else, the configuration operate of your product or service will be lost. After eliminating the CPU module, Remove panhead screws with washers (twelve M3X6) fixed on the most crucial unit box, you normally takes from the board. Site 118 Determine 8-29 Disassemble the User interface Assembly (one) Hold the upper edge of user interface assembly, and open up the user interface. Determine 8-thirty Disassemble the User interface Assembly (2) After getting rid of one particular countersunk head self-tapping screw PT3X10 fastened within the control panel and just take out the plug from the keyboard and the principle unit connecting cables, you can eliminate the user interface assembly.
General performance Exam five.5.one Examination Course of action Resolution Detection depth Geometric Situation Precision Blackout location check Document the Examination photos 5.five.two Exam Information The image applied here is only for reference, keep on with the picture effect in the actual Observe: circumstance. Needs: Display screen: set the distinction and brightness within the medical application price (or the default status) Procedure natural environment: dark place, simulating the clinical software natural environment. Web site 76 In situation that the transverse resolution screening targets are horizontally exhibited, report the minimal distance of two targets that can be Obviously recognized. Repeat the Procedure over for your transverse resolution screening targets at other depths. As demonstrated in figure down below. Axial resolution ... Website page 77 When using the convex probe, keep the transverse resolution testing targets to notice: be displayed close to the midline. When utilizing a linear probe with steer purpose, don't activate the steer functionality when conduct the transverse resolution take a look at. Zoom within the location in which the targets Found if required. The diameter of your target stage at a certain depth is equivalent towards the transverse resolution at the depth. Website page 78 5.
Mindray respects your privacy. We use cookies for a number of uses, like Web page performance, improving upon your practical experience of our Site, making integration with social media and supporting goal our marketing.
5.two.three Geometric positioning accuracy Longitudinal geometric positioning precision Check Action: Do changes as the best way in tests the most depth. File the space by 20mm Every single segment to the longitudinal targets line using the measurement caliper; Pick out the worth with the best mistake (to 20mm), compute the accuracy using the components below The measurement caliper ought to be positioned with the higher edge of the concentrate on, Take note:... Web page 79 Transverse geometric positioning precision Take a look at Move: Cover the scan area from the phantom with water or pair gel, gently Speak to the probe Using the scan area Change the depth, generating the Dp50rb transverse targets being shown in the graphic. Alter the focus position to get posited beside the transverse targets (the normal is not apparent) Alter parameters like attain, TGC, generating Each and every transverse targets to generally be Evidently displayed. Website page eighty five.five.two.four Blackout Area Examination Stage: Protect the scan surface with the phantom with water or couple gel, Carefully Speak to the probe Along with the scan area Alter the depth at a reduce worth, and established the focus at the closest spot to the scan floor. Reduce the worth of parameters like AP, Acquire until eventually the track record sound just is usually observed. Web site 81: Software package Up grade And Maintenance